Clinical note · #101
Surgery (CPT)
Operative report
Patient: 76-year-old woman whose left total hip was put in 14 years ago at another hospital, with a metal head on a polyethylene liner. For a year she has had thigh and groin pain on walking. X-rays show a clear gap around the cup and the stem, and the cup has tilted. Blood tests and a hip aspiration done before admission showed no infection.
Preoperative and postoperative diagnosis: Aseptic loosening of the femoral and acetabular components, left total hip arthroplasty.
Procedure: Revision left total hip arthroplasty, both components.
Anesthesia: General.
Removed: Old acetabular cup and liner, femoral stem and metal head.
Implants: Multi-hole porous titanium revision shell with three screws; highly cross-linked polyethylene liner; modular titanium revision stem, press-fit; 32 mm ceramic head. No bone cement.
Description: The old posterior scar was opened and the hip dislocated. A thick membrane of scar and wear debris surrounded the implants and was cleared away. The head was taken off the stem. The stem was loose and came out with light blows; the cup lifted out with a curved osteotome. Tissue samples were sent for culture. The acetabulum was reamed to bleeding bone with good rim support, and the revision shell was pressed in and held with three screws. The femoral canal was prepared and the revision stem was seated tightly in the shaft. The trial showed a stable hip with equal leg lengths. The final ceramic head was placed and the hip reduced. Closure in layers over a drain.
Cultures: No growth at five days.
Signed by the attending orthopedic surgeon