Skip to content
MedicalCoreCoding

Try a topic like assisted living, critical care or a code like 99214.

National Colony, Aurangabad, 431001 · Mon - Fri: 9am - 5pm

Report #106 · Surgery (CPT)

New dual-chamber pacemaker for complete heart block

Coding exercise: CPT, modifiers and ICD-10-CMCode

Practice report: the patient, providers and dates are made up for teaching. No real patient data is used.

Jump to the coding form

Clinical note · #106

Surgery (CPT)

Procedure report

Patient: 79-year-old woman admitted after two fainting spells at home. ECG and monitoring show complete heart block with a ventricular rate of 34. No reversible cause found: no AV-node-blocking drugs, potassium normal, no signs of a heart attack. No previous pacemaker or defibrillator.

Preoperative and postoperative diagnosis: Symptomatic complete (third-degree) atrioventricular block.

Procedure: Implantation of a new dual-chamber permanent pacemaker: right atrial and right ventricular transvenous leads.

Sedation: Moderate sedation given by the anesthesia team.

Description: The left chest was prepared. Under ultrasound, the left axillary vein was entered and two guidewires placed. A pocket was made under the skin below the left collarbone. Under fluoroscopy, an active-fixation lead was placed in the right ventricular septum (threshold 0.6 V, R wave 9 mV) and a second in the right atrial appendage (threshold 0.8 V, P wave 3 mV). Both leads were sutured to the muscle, connected to a new dual-chamber generator, and the device was placed in the pocket. The pocket was washed with antibiotic solution and closed in layers. Device checked and programmed DDD at 60 beats per minute.

Signed by the attending electrophysiologist