Clinical note · #141
Surgery (CPT)
Operative report
Patient: 19-year-old man hit in the jaw by another player's elbow during a tackle football game. His bite is off and the right side of the jaw is painful and numb. CT: a displaced fracture of the angle of the right mandible. No other fractures. The skin and the lining of the mouth are intact.
Preoperative and postoperative diagnosis: Displaced fracture, right mandibular angle.
Procedure: Placement of upper and lower arch bars with interdental (maxillomandibular) fixation; open reduction and internal fixation of right mandibular angle fracture through an intraoral approach with a plate.
Anesthesia: General, nasal tube, by anesthesia.
Description: Arch bars were wired to the upper and lower teeth, and the bite was set in its normal position and held with wires between the bars. Through an incision inside the mouth over the right angle, the fracture was exposed and lined up, and a 6-hole plate was fixed along the upper edge of the jaw. The inter-jaw wires were then released; the bite stayed correct. The arch bars were left on for 4 weeks. Closure of the mouth incision.
Signed by the attending oral and maxillofacial surgeon