Clinical note · #147
Surgery (CPT)
Operative report
Patient: 77-year-old woman who tripped at home and fell onto her right shoulder. X-rays and CT: four-part fracture of the right proximal humerus (head, shaft, and both tuberosities in separate pieces), with the head pushed out of position. The glenoid is undamaged. Bone quality is poor, so fixation with a plate is unlikely to hold.
Preoperative and postoperative diagnosis: Closed four-part fracture, right proximal humerus.
Procedure: Open treatment of right proximal humerus fracture with humeral head prosthetic replacement (hemiarthroplasty) and repair of the tuberosities.
Anesthesia: General with an interscalene block, by anesthesia.
Description: Through a deltopectoral approach, the broken head was removed. The greater and lesser tuberosities were tagged with heavy sutures. The humeral canal was prepared and a fracture-type stem was cemented at the right height and angle, with a metal head matched to the old one. The tuberosities were fixed back around the stem and to the shaft with the sutures, and bone from the broken head was packed underneath. The glenoid was not replaced. The joint was stable. Closure in layers.
Signed by the attending orthopedic surgeon