Clinical note · #157

Surgery (CPT)

Colonoscopy report

Patient: 76-year-old man admitted with large bright red bleeding from the rectum. Hemoglobin fell from 13.1 to 8.9 g/dL; one unit of blood given. Colon prepared overnight.

Indication: Lower GI bleeding.

Procedure: Colonoscopy to the cecum; control of bleeding from a sigmoid diverticulum with clips; hot snare polypectomy in the descending colon.

Sedation: Monitored anesthesia care by anesthesia.

Findings and treatment: Many diverticula in the sigmoid colon. One had a visible vessel with fresh blood oozing. Dilute epinephrine was injected around it and three clips closed it; the bleeding stopped. In the descending colon, a 9 mm polyp on a short stalk was removed with a hot snare. The stalk then oozed, so one clip was placed, which stopped it. The rest of the colon to the cecum was normal.

Pathology: Tubular adenoma, descending colon, completely removed.

Impression: Bleeding diverticulosis, treated. Descending colon adenoma, removed.

Signed by the attending gastroenterologist