Clinical note · #201
Surgery (CPT)
Operative report
Patient: 29-year-old man who slipped on an icy driveway and twisted his right leg. X-rays: a closed, displaced spiral fracture of the shaft of the right tibia and a closed, displaced spiral fracture of the shaft of the right fibula at a higher level.
Preoperative and postoperative diagnosis: Closed displaced spiral fracture of the right tibial shaft with a fibular shaft fracture.
Procedure: Right tibial reamed intramedullary nailing with proximal and distal interlocking screws.
Anesthesia: General anesthesia.
Description: Under fluoroscopy, an incision was made over the patellar tendon. A guide wire was passed down the tibial canal across the fracture after it was reduced. The canal was reamed and a nail was placed. Two screws were placed proximally and two distally through the nail. Alignment and length were checked and were good. The fibula was not exposed and was not fixed; it was expected to heal on its own. Closure in layers.
Signed by the attending orthopedic surgeon