Clinical note · #92

Surgery (CPT)

Operative report

Patient: 66-year-old man with a known midline hernia in a scar from a colon operation eight years ago. He came in with 12 hours of a painful lump that would not go back, vomiting and no stool or gas. CT showed a loop of small bowel trapped in the hernia with signs of poor blood supply and dilated bowel above it.

Preoperative diagnosis: Incarcerated incisional hernia with small bowel obstruction, possible strangulation.

Postoperative diagnosis: Strangulated incisional hernia with gangrene of the distal ileum.

Procedure: Exploratory laparotomy; release of the hernia and reduction of contents; segmental small bowel resection with stapled side-to-side anastomosis; repair of the incisional hernia with retromuscular polypropylene mesh.

Anesthesia: General endotracheal, rapid sequence.

Description: The old scar was opened. The hernia sac held about 25 cm of distal ileum, dark and swollen, trapped by a tight 4 cm ring of fascia. The ring was cut to free the loop, and the bowel was brought back into the abdomen and wrapped in warm packs. After 15 minutes, 12 cm of the ileum stayed black with no pulse in its vessels and a thinning wall. The rest of the trapped loop pinked up and had good pulses.

The 12 cm dead segment was removed between staple lines, starting about 40 cm from the ileocecal valve, and the two ends were joined side to side with staplers. The common opening was closed with sutures. The rest of the bowel was run from the ligament of Treitz to the cecum and was healthy.

The field was washed out and gloves and instruments were changed. Because the field was clean-contaminated, a medium-weight polypropylene mesh was chosen after discussion of the risk. The space behind each rectus muscle was opened and the mesh was laid there, overlapping the 4 cm defect by 5 cm on every side. The fascia in front of the mesh was closed in the midline. The skin was closed with staples over two subcutaneous drains.

Pathology: Segment of ileum with transmural hemorrhagic necrosis. Margins viable.

Signed by the attending general surgeon