Clinical note · #96
Surgery (CPT)
Operative report
Patient: 63-year-old man, a retired bus driver, with left groin pain for two years, a limp and difficulty putting on socks. X-rays show complete loss of the left hip joint space with cysts and osteophytes. The right hip is normal. No injury, no rheumatoid disease.
Preoperative and postoperative diagnosis: Primary osteoarthritis, left hip.
Procedure: Left total hip arthroplasty, uncemented.
Anesthesia: Spinal.
Implants: Porous-coated titanium acetabular shell, press-fit, with one screw; highly cross-linked polyethylene liner; porous-coated titanium femoral stem, press-fit; 36 mm ceramic femoral head. No bone cement was used.
Description: Posterolateral approach with the patient on the right side. The short external rotators and capsule were taken down and tagged. The hip was dislocated and the femoral neck was cut at the planned level. The acetabulum was reamed up to 54 mm and the shell was impacted with good press-fit; one screw was added. The liner was locked in. The femoral canal was broached up to size 5 and the final stem impacted. With a trial head the hip was stable and leg lengths were equal. The ceramic head was put on the cleaned taper and the hip reduced. The capsule and rotators were repaired to bone. Layered closure.
Signed by the attending orthopedic surgeon